ExelTech XP 2000 Especificaciones Pagina 3

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 23
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 2
The Exeltech MX Series of inverters is available in three basic architectures; redundant, upgradable and
expandable. Different options and sizes are available to fit varying applications. As a benefit of the MX
series modular design, power levels are expandable in any system, as power requirements increase.
1.) N+1 Redundant-Expandable Inverter System: For applications where reliability and maintainability
are paramount, the N+1 redundant system offers the most cost effective method of achieving redundancy
and the ability to maintain the system while loads remain on line. All cards (except 12 Vdc) are "hot"
insertable to allow maintenance without interrupting power to critical loads. Designing the power level with
N+1 number of power modules, allows for redundancy without necessitating the purchase of a duplicate
system. (An A/B Buss option is available, which adds to system reliability).
2.) Upgradable Inverter System: The Upgradable system offers the flexibility to add a X-fer switch or
alarm card and Full Redundancy for future requirements. A minimum system with as little as one control
card and one power module can be upgraded in the future to include additional power modules, X-fer switch
or alarm card and an additional control card for full redundancy (see figure II).
Overload
Load
On
MX 1000 Power Module
Overload
Load
On
MX 1000 Power Module
Overload
Load
On
MX 1000 Power Module
Overload
Load
On
MX 1000 Power Module
Overload
Load
On
MX 1000 Power Module
MX
CONTROL
CARD
MX
CONTROL
CARD
MX ALARM CARD
On
Off
INV
Low
Volt
High
Temp
BRKR
Open
INV
Fail
Load
INV
On
DC
On
AC POWER
CB1
1 ea. Alarm Card or
System Monitor Card
part # H (100 Vac)
A (120 Vac)
B (120 Vac)
C (120 Vac)
F (230 Vac)
2 ea. Control Cards
part # LL (100 Vac)
CC (120 Vac)
EE (230 Vac)
At least 3 Power Modules
part # P (100 Vac)
P (120 Vac)
R (230 Vac)
1 ea. Cage assembly
part # 1A (19" cage)
2A (23" cage)
Options: 1 ea. X-fer switch
part # G (100 Vac)
S (120Vac)
X (120 Vac)
Z (230 Vac)
expansion rack
part # 1B (19" cage)
2B (23" cage)
X-fer switch includes alarms
and replaces the alarm card.
...integrates with rack A for accommodating additional
power modules, up to total rating of 20KW. Additional
control cards and a larger X-fer switch may be required.
Please call the factory for assistance.
A redundant system consists of:
MX SERIES SYSTEM DESCRIPTION
Page 3
Vista de pagina 2
1 2 3 4 5 6 7 8 ... 22 23

Comentarios a estos manuales

Sin comentarios