In addition to the Standard features offered by the XP family of inverters,
therearefeaturesspecifictothechargerandtransferswitchfunctionality
Positive (+) and Negative (-) input terminals are 5/6" studs
with brass hardware. They are accessed under the rear cover. Use
Appendix A” to choose the appropriate gauge wire for your specific
model.
Provides the user with a remote method to turn the
inverter on and off. “REMOTE” connection is on the barrier terminal strip
located under the rear cover.
.
All domestic models have two NEMA - 20A receptacles
on the front plate and a barrier strip terminal on the backplane. They are
tied to the inverters output as well as the chargers input, which means
that there will always be AC present on these outlets as well as the
LOAD” connections on the backplane. The AC will come from the
primary source when present and from the inverter when the primary
source is not present.
DC INPUTS:
REMOTE ON/OFF:
AC OUTPUTS:
.
.
.
StandardFeatures
2.0
supply its peak current to the load for 3 seconds then it will scale back
to its rated current for an additional 4 seconds. If the short is not cleared
within that 7 seconds the inverter will shut off requiring the user to cycle
the power button to turn it back on. Exeltechs inverters can output their
full rated power continuously at 30° C (86° F). The inverter is derated
20% of its full power for every 10° C over 30° C. IE; 80% of normal
capacityat40°C,60%at50°C...Etc.
.